0
image
image
Smart Metering Residual Current Operated Circuit Breaker

Smart MCB switch DGB3-80ZL

DGB3-80ZL
DGB3-80ZL series functional metering Residual current Operated Circuit- breaker is mainly used in AC 50Hz with rated working voltage 230V and with rated current up to 80A. In case of personal electric shock or when the grid leakage current exceeds the specified value, the residual current action circuit breaker can work to quickly cut off the power supply within the very short time for protection of the safety of personnel and electrical equipment as infrequent conversion of the line under the overload, short-circuit, overvoltage and normal situations, especially suitable for industrial and business lighting power distribution system.
Quantity:
Contact Now
add to cart
 
Can be connected to mobile phone software operation, 5G networking, convient and fast.  WIFI, RS485 and other communication interfaces, Real-time collection of voltage, current, power,power consumption and other data
 

Product name

DGB3-80ZL

Standards

GB /T 10963.1NB/T42149IEC 60898-1

Certificate

CE, CCC, CB

Main function

safety function

remote control device switch on and off

switch on and off on site

safty lock --- mechnesim lock force to switch off

Over and undervotalge protection

Phase loss protection

over load and Short circuit protection function

Three-phase imbalance alarm function

Lightning surge protection function

over temperature alarm function

Leakage protection and self inspection function

Metering function

Arc fault detection function

Data collection

Voltage

Current

Temperature

Leakage

IoT interaction function

current limiting function

Energy Metering function

Query electricity data function

Safe operation data record query function

Phone App

Platform centralized management function

Local edge computing function

Product name

DGB3-80ZL

Standards

GB /T 10963.1NB/T42149IEC 60898-1

Certificate

CE, CCC, CB

Electrical characteristics

Number of poles

1P+N2P3P3P+N4P

Rated frequency (Hz)

50/60

Frame current (A)Inm

80

Rated current (A)In

6,10,16,20,25,32,40,50,63,80

Rated voltage (V)

AC230/400(1P+N/2P) ; AC400(3P,3P+N4P)

Rated insulation voltage (V)Ui

500

Rated impulse withstand voltage (kV)Uimp

4

Rated short-circuit breaking capacity (kA)   Ics

6

Rated short-circuit breaking capacity (kA)   Icn

6

Instantaneous trip characteristics

B,C,D

Trip form

Thermal, magnetic and Leakage trip

Pollution level

2

Rated residual action current (mA)

30/50/100/300

Max. breaking time at the rated residual current

0.1s

Wave form of earth leakage sensed

AC / A

Overvoltage protection: Uvo=280V±5%

optional